• View Range
(associated Level: Main Floor T.O. Sheathing) Floor Plan
Top: Main Floor (T.O. Sheathing offset 7’6”)
Cut Plane (associated Offset 6’)
Bottom: (associated offset: 0’0”)
View Depth Level: (associated offset 0’0”)
• Cut Plane: cut through walls to show all openings, looking down
• Visual Style: hidden line
• Phase Filter: Show New
• Rooms
• Smoke detectors & CO detectors
• Attic access
• Crawlspace access
• Exhaust fans (kitchen, bathroom, laundry)
• Routing for exhaust ducts
• Kitchen appliances (distinguish new/existing)
• Bathroom fixtures (distinguish new/existing)
• Laundry machines (distinguish new/existing)
• Routing for laundry exhaust
• Countertops (distinguish new/existing)
• Upper cabinets (distinguish new/existing)
• Water heater (distinguish new/existing)
• Electrical Panel (distinguish new/existing)
• Furnace (distinguish new/existing)
• Drop beams for story above (will be above cut plane)
• Trace all drop beams with linework (use overhead line, distinguish new/existing)
• Trace skylights above with linework (distinguish new/existing)
• Trace roof outlines with linework (distinguish new/existing)
• Trace major changes in roof plane above (distinguish new/existing)
• Shelf & rod in closets
• Hose bibbs
• Gas cocks
• Dimensions
Clear dimensions of new rooms and hallways (use clear span dimensions with arrow ends)
New casework extents (island dimensions, spacing between island and counters, etc.)
• Labels
Rooms (at rooms where no work will occur, note (no work) below room name)
Tag windows (Floor Plan Tag)
Note safety glazing
Note egress windows
Tag doors
Smoke detectors & CO detectors
Exhaust fan CFM
Note whole-house ventilation fan
Stair direction, rise and run, tread/riser sizes
Ceiling height (where not uniform throughout) & slope, where applicable
Patios
Decks
Steps (at door threshold, for instance)
Hose bibbs
Gas cocks
Check:
- Doors are typically 3″ (2) studs from wall
- Washer/Dryer are 4″ from wall (space for dryer vent)